-40 °C to +90 °C
Max. temp. at conductor +120 °C
According to VDE U0/U 600/1000 V AC
1800 V DC conductor/conductor
10000 V
fixed installation approx. 4 x outer diameters
flexing 10 x cable diameter
Bare copper, tinned, finely stranded according to DIN VDE 0295 class 5 and IEC 60228 cl. 5
Double-insulated
Insulation cross-linked Polyolefin
Outer sheath cross-linked Polyolefin
Sheath colour black, red or blue
According to PV1-F requirement profile for PV cables DKE/VDE AK 411.2.3
VDE (Reg. 8266)
TÜV (2 PfG 1169/08.2007, R60025298)
RoHS and CE compliant
Ozone resistant acc. to EN 50396
Weather and UV resistant acc. to HD 605/A1
Halogen-free acc. to EN 50267-2-1, EN 60684-2
Resistant to acid and bases acc. to EN 60811-2-1
Flame-resistant acc. to VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1
Very robust and abraison-resistant sheath acc. to DIN EN 53516
Resistant to short-circuits up to 200°C thanks to their double insulation; short-circuits temperature 200°C/ 5 sec.
Anticipated service life - 25 years
Hydrolysis and ammoniac resistant
The SOLARFLEX®-X PV1-F is used for cabling solar modules.
Part No. | No. cores x cross-sec. mm² |
Outer Ø app. mm |
Cop. weight kg / km |
Weight app. kg / km |
Current-carrying capacity [A] at 60°C |
Conductor resistance Ω / km at 20°C |
Core / jacket colour |
---|---|---|---|---|---|---|---|
704225 | 1 x 2,5 | 4,5 | 24,0 | 42 | 41 | 8,210 | natural/black |
705891 | 1 x 2,5 | 4,5 | 24,0 | 42 | 41 | 8,210 | natural/red |
705892 | 1 x 2,5 | 4,5 | 24,0 | 42 | 41 | 8,210 | natural/blue |
704226 | 1 x 4 | 5,2 | 38,4 | 60 | 55 | 5,090 | natural/black |
705775 | 1 x 4 | 5,2 | 38,4 | 60 | 55 | 5,090 | natural/red |
705776 | 1 x 4 | 5,2 | 38,5 | 60 | 55 | 5,090 | natural/blue |
704227 | 1 x 6 | 5,9 | 57,6 | 82 | 70 | 3,390 | natural/black |
705777 | 1 x 6 | 5,9 | 57,6 | 82 | 70 | 3,390 | natural/red |
705778 | 1 x 6 | 5,9 | 57,6 | 82 | 70 | 3,390 | natural/blue |
704228 | 1 x 10 | 6,9 | 96,0 | 123 | 98 | 1,950 | natural/black |
705893 | 1 x 10 | 6,9 | 96,0 | 123 | 98 | 1,950 | natural/red |
705894 | 1 x 10 | 6,9 | 96,0 | 123 | 98 | 1,950 | natural/blue |
704229 | 1 x 16 | 8,3 | 153,6 | 190 | 132 | 1,240 | natural/black |
706839 | 1 x 16 | 8,3 | 153,6 | 190 | 132 | 1,240 | natural/red |
706840 | 1 x 16 | 8,3 | 153,6 | 190 | 132 | 1,240 | natural/blue |
704230 | 1 x 25 | 10,0 | 240,0 | 285 | 176 | 0,795 | natural/black |
704231 | 1 x 35 | 11,0 | 336,0 | 376 | 218 | 0,565 | natural/black |
704232 | 1 x 50 | 13,0 | 480,0 | 530 | 276 | 0,393 | natural/black |
704233 | 1 x 70 | 15,3 | 672,0 | 745 | 347 | 0,277 | natural/black |
704234 | 1 x 95 | 17,0 | 912,0 | 960 | 416 | 0,210 | natural/black |
705738 | 1 x 120 | 19,1 | 1152 | 1220 | 488 | 0,164 | natural/black |
705739 | 1 x 150 | 22,7 | 1440 | 1550 | 566 | 0,132 | natural/black |
706288 | 1 x 185 | 25,5 | 1776 | 1930 | 644 | 0,108 | natural/black |
706289 | 1 x 240 | 28,3 | 2304 | 2550 | 775 | 0,0817 | natural/black |
Version with rodent protection available
UL version on request
All types with metre marking
Eland Part No. | No. Of Cores | Nominal Cross Sectional Area mm2 |
Nominal Overall Diameter mm |
Nominal Weight kg / km |
---|---|---|---|---|
A6S10025 | 1 | 2.5 | 4.5 | 39 |
A6S10040 | 1 | 4 | 5.2 | 57 |
A6S10060 | 1 | 6 | 5.9 | 79 |
A6S1010 | 1 | 10 | 6.9 | 122 |
A6S1016 | 1 | 16 | 8.3 | 181 |
A6S1025 | 1 | 25 | 9.7 | 273 |
A6S1035 | 1 | 35 | 11 | 364 |
A6S1050 | 1 | 50 | 13.2 | 520 |
A6S1070 | 1 | 70 | 15.4 | 713 |
A6S1095 | 1 | 95 | 17.4 | 930 |
A6S1120 | 1 | 120 | 20.1 | 1191 |
A6S1150 | 1 | 150 | 22.5 | 1514 |
A6S1185 | 1 | 185 | 26 | 1828 |
A6S1240 | 1 | 240 | 26.8 | 2324 |
Class 5 Flexible Copper Conductors for Single Core and Multi-Core Cables
Nominal Cross Sectional Area mm2 |
Maximum Resistance Of Conductor At 20℃ | |||||||
Metal-Coated Wires ohms/Km |
||||||||
2.5 | 8.21 | |||||||
4 | 5.09 | |||||||
6 | 3.39 | |||||||
10 | 1.95 | |||||||
16 | 1.24 | |||||||
25 | 0.795 | |||||||
35 | 0.565 | |||||||
50 | 0.393 | |||||||
70 | 0.277 | |||||||
95 | 0.21 | |||||||
120 | 0.164 | |||||||
150 | 0.132 | |||||||
185 | 0.108 | |||||||
240 | 0.0817 |
The above table is in accordance with BS EN 60228 (previously BS 6360)
No. Of Cores | Nominal Cross Sectional Area mm2 |
Current Carrying Capacity | |
In Air Amps |
|||
1 | 2.5 | 41 | |
1 | 4 | 55 | |
1 | 6 | 70 | |
1 | 10 | 98 | |
1 | 16 | 132 | |
1 | 25 | 176 | |
1 | 35 | 218 | |
1 | 50 | 276 | |
1 | 70 | 347 | |
1 | 95 | 416 | |
1 | 120 | 488 | |
1 | 150 | 566 | |
1 | 185 | 644 | |
1 | 240 | 775 |
Based on a 60℃ ambient temperature
AIR TEMPERATURE | UPTO 60 | 70 | 80 | 90 | 100 | 110 |
DE-RATING FACTOR | 1.00 | 0.91 | 0.82 | 0.71 | 0.58 | 0.41 |