Johnson H05V2V2-F Cable
GENERALLY CONFORMS TO H05V2V2-F EN 50525-2-11, IEC 60227, IEC 60228
Multi Core Heat Resistance PVC Insulated & PVC Sheathed Flexible Cords
Cable Structure
FLEXIBLE COPPER
HR PVC TYPE TI-3
HR PVC TYPE TM-3
Application
PVC cable for use in domestic appliances, kitchens and offices. For use with light portable appliances, such as office equipment, applications.
Cable Construction
- Conductor: Class 5 Flexible bare Copper IEC 60228
- Insulation: HR PVC type TI 3 to EN 50363-3 (H05V2V2-F)
- Sheath: HR PVC type TM 3 to EN 50363-4-1 (H05V2V2-F)
TECHNICAL DATA
Voltage:
300/500 V
Test Voltage:
2000 V
Operating Temperature Range:
-15°C ❄️ to +90°C 🔥 (H05V2V2-F)
Flame Propagation:
Flame Retardant test as per IEC 60332-1
Volume Resistivity at 27°C:
Min. 1 x 1010 Ω-cm
Tensile Strength Min.:
12.50 N/mm²
Elongation at Break Min.:
150%
Minimum Bending Radius:
≥ 8 X Cable Dia
CABLE FEATURES
- Design for Harmonized Acc. to European Standards
- Very good Heat Resistance Property for Insulation
- Special Grade Insulation HR PVC type TI 3 to EN 50363-3
- Special Grade Sheath HR PVC type TM 3 to EN 50363-4-1
- Very good Insulation Resistance Property
- Excellent Resistance to Moisture, Abrasion, Grease, Oil
- Excellent Mechanical & Electricals property
- Very good Current carrying capacity
- Very good Thermal property for Insulation
INSULATION COLOR CODE
- 2 Core : Blue Brown
- 3 Core : Yellow/Green Strip Blue Brown
- 4 Core : Yellow/Green Strip Brown Black Gray
- 5 Core : Yellow/Green Strip Blue Brown Black Gray
Or as per customer requirement.
SHEATH COLOR CODE
- 2 Core : White Blue Gray
- 3 Core : White Blue Gray
- 4 Core : White Blue Gray
- 5 Core : White Blue Gray
Or as per customer requirement.
PACKING DETAILS
100 Meter
200 Meter
500 Meter
1000 Meter
2000 Meter
Or as per customer requirement.
Technical Specifications (Multi Core H05V2V2-F)
Multi Core Heat Resistance PVC Insulated & PVC Sheathed Flexible Cords Specifications
| SIZE (NO. OF CORE X SQ.MM) |
TOTAL NO. OF STRANDS |
MAXIMUM DIA IN MM (NOM.) |
(NOM.) INSULATION THICKNESS mm |
(NOM.) SHEATH THICKNESS mm |
OUTER SHEATH DIA IN mm (APPROX OD) |
MAXIMUM DC RESISTANCE CONDUCTOR AT 20° C Ω/km |
|---|---|---|---|---|---|---|
| 2 CORE | ||||||
| 2 X 0.75 | 24 | 0.200 | 0.60 | 0.80 | 6.30 | 26.00 |
| 2 X 1 | 32 | 0.200 | 0.60 | 0.80 | 7.20 | 19.50 |
| 2 X 1.5 | 30 | 0.250 | 0.70 | 0.80 | 7.80 | 13.30 |
| 2 X 2.5 | 50 | 0.250 | 0.80 | 1.00 | 9.40 | 7.98 |
| 2 X 4 | 56 | 0.300 | 0.80 | 1.10 | 10.60 | 4.95 |
| 3 CORE | ||||||
| 3 X 0.75 | 24 | 0.200 | 0.60 | 0.80 | 6.70 | 26.00 |
| 3 X 1 | 32 | 0.200 | 0.60 | 0.80 | 7.60 | 19.50 |
| 3 X 1.5 | 30 | 0.250 | 0.70 | 0.90 | 8.40 | 13.30 |
| 3 X 2.5 | 50 | 0.250 | 0.80 | 1.00 | 9.90 | 7.98 |
| 3 X 4 | 56 | 0.300 | 0.80 | 1.20 | 11.40 | 4.95 |
| 4 CORE | ||||||
| 4 X 0.75 | 24 | 0.200 | 0.60 | 0.80 | 7.30 | 26.00 |
| 4 X 1 | 32 | 0.200 | 0.60 | 0.90 | 8.50 | 19.50 |
| 4 X 1.5 | 30 | 0.250 | 0.70 | 1.00 | 9.40 | 13.30 |
| 4 X 2.5 | 50 | 0.250 | 0.80 | 1.10 | 11.10 | 7.98 |
| 4 X 4 | 56 | 0.300 | 0.80 | 1.20 | 12.50 | 4.95 |
| 5 CORE | ||||||
| 5 X 0.75 | 24 | 0.200 | 0.60 | 0.90 | 8.20 | 26.00 |
| 5 X 1 | 32 | 0.200 | 0.60 | 0.90 | 9.30 | 19.50 |
| 5 X 1.5 | 30 | 0.250 | 0.70 | 1.10 | 10.50 | 13.30 |
| 5 X 2.5 | 50 | 0.250 | 0.80 | 1.20 | 12.40 | 7.98 |
| 5 X 4 | 56 | 0.300 | 0.80 | 1.40 | 14.20 | 4.95 |
IMPORTANT TECHNICAL NOTES
NOTE: The Above Data is Approximate & Subject to Manufacturing Tolerance. The number of wire is approximate and wire diameter is nominal, They shall be such as to satisfy the requirements of conductor resistance of IEC 60228/DIN VDE 0295/IS 8130/BS 6360.