MULTI CORE | FR
MULTICORE FLEXIBLE CABLES (IS:694)
PVC Insulated and PVC sheathed flexible copper cable (up to 1100 volts)
CONDUCTOR
The conductors are draw from 99.97% bright electrolytic grade copper with more than 101% conductivity are annealed and bunched together (Class 2&5).
OPERATING TEMPERATURE RANGE
-15°C to Max. +70°C/+85°C
AVAILABLE COLOURS
Or as per customer requirement.
FEATURES
- 99.97% pure bright annealed copper for low conductor resistance.
- Abrasion-resistant PVC sheath offers protection against water, oil, and grease.
- Delivers excellent mechanical strength and electrical performance.
- Sequential meter marking enables easy and accurate length identification.
INSULATION TYPE
INSULATION PVC
- Specially formulated PVC insulation provides high insulation resistance for enhanced safety and reliability.
- Manufactured using advanced high-speed extrusion lines for precise insulation application.
- Ensures excellent dimensional accuracy and consistent performance throughout the cable.
SHEATH PVC
- Resistant to oil and moisture for reliable protection in demanding environments.
- Delivers superior mechanical strength while maintaining excellent flexibility.
Technical Specifications
| NOMINAL CROSS SECTIONAL AREA mm² |
NUMBER/ NOMINAL DIA OF WIRES (MAX) Number/mm |
THICKNESS OF INSULATION (NOMINAL) mm |
THICKNESS OF SHEATH (mm) |
APPROX OVERALL DIAMETER (mm) |
MAXIMUM DC RESISTANCE CONDUCTOR AT 20° C Ω/km |
MAX. CURRENT CARRYING CAPACITY Amps |
||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2 CORE | 3 CORE | 4 CORE | 5 CORE | 2 CORE | 3 CORE | 4 CORE | 5 CORE | |||||
| 0.5 | 16/0.2 | 0.6 | 0.90 | 0.90 | 0.9 | 0.9 | 6.00 | 6.30 | 6.8 | 7.6 | 39 | 4 |
| 0.75 | 24/0.2 | 0.6 | 0.90 | 0.90 | 0.9 | 0.9 | 6.30 | 6.70 | 7.3 | 8.2 | 26 | 7 |
| 1* | 14/0.3 | 0.6 | 0.90 | 0.90 | 0.9 | 1.0 | 7.10 | 7.60 | 8.2 | 9.6 | 18.10 | 12 |
| 1.5* | 22/0.3 | 0.6 | 0.90 | 0.90 | 1.0 | 1.0 | 7.70 | 8.10 | 9.6 | 11.0 | 12.10 | 16 |
| 2.5* | 36/0.3 | 0.7 | 1.00 | 1.0 | 1.0 | 1.0 | 8.80 | 9.50 | 10.6 | 12.5 | 7.41 | 22 |
| 4 | 56/0.3 | 0.8 | 1.00 | 1.0 | 1.0 | 1.10 | 10.20 | 11.20 | 12.2 | 14.6 | 4.95 | 29 |
| 6 | 84/0.3 | 0.8 | 1.10 | 1.2 | 1.2 | - | 12.50 | 13.50 | 15.3 | - | 3.30 | 37 |
| 10 | 140/0.3 | 1.0 | 1.30 | 1.4 | 1.4 | - | 16.40 | 17.0 | 19.2 | - | 1.91 | 50 |
| 16 | 224/0.3 | 1.0 | 1.40 | 1.4 | 1.4 | - | 19.40 | 20.6 | 22.9 | - | 1.21 | 65 |
| 25 | 350/0.3 | 1.2 | 1.40 | 1.5 | 1.6 | - | 23.80 | 25.0 | 28.0 | - | 0.780 | 86 |
| 35 | 490/0.3 | 1.2 | 1.60 | 1.6 | 1.7 | - | 27.20 | 28.0 | 30.8 | - | 0.554 | 110 |
| 50 | 703/0.3 | 1.4 | 2.00 | 2.0 | 2.0 | - | 32.50 | 32.0 | 37.0 | - | 0.386 | 140 |
Important Technical Notes
- ALL ARE CLASS 5 CONDUCTOR *CLASS 2
- 1. The number of wires and diameter mentioned in the table are approximate and nominal, however they shall meet the requirements of conductor resistance as per standards. IS 8130
- Tolerance: Up to 4.0 sq.mm +/-0.5 mm, 6.0 sq.mm and 10 sq.mm +/-1.0 mm and above 10 sq.mm +/-1.2 mm.
- 2. The above data is indicative and may be revised without prior information. Johnson Cables will not be liable for any damages arising out of incorrect application.