PVC Insulated unsheathed flexible copper cable (up to 1100 volts)

Conductor Specification

The conductor drawn from 99.97% bright electrolytic grade copper with more than 100% conductivity are annealed and bunched together. (Class 2 Flexible)

Operating Temperature

-15°C to Max. +70°C

Insulation Standard

HFFR (Halogen Free Flame Retardant)

AVAILABLE COLOURS
Red
Yellow
Blue
Black
Green
White

FEATURES

  • 99.97% pure bright annealed copper for low conductor resistance.
  • Insulated with in-house manufactured, high-grade PVC compound for superior insulation resistance.
  • Offers excellent mechanical strength and electrical performance.
  • Features sequential meter marking for easy length tracking and usage.

INSULATION TYPE

FR-LSH CLASS 2
  • Flame Retardant Low Smoke & Halogen (FR-LSH) insulation designed to withstand temperatures up to 70°C.
  • High insulation resistance ensures enhanced electrical safety and reliability.
  • Enables higher current-carrying capacity for improved performance.
  • The bunch conductors are insulated with specially formulated flame retardant low smoke compound.
  • During a fire situation, the FR-LSH compound restricts the spread of flame. The smoke emission is also minimal.
  • Delivers superior electrical and mechanical performance at elevated temperatures.

Technical Specifications

NOMINAL CROSS SECTIONAL AREA mm² NUMBER/ NOMINAL DIA OF WIRES (MAX) Number/mm THICKNESS OF INSULATION (NOMINAL) mm APPROX OVERALL DIA mm MAXIMUM DC RESISTANCE CONDUCTOR AT 20° C Ω/km MAX. CURRENT CARRYING CAPACITY AMPS
CASING CONCEALED
0.516/0.2 **0.62.1039.0044
0.7524/0.2 **0.62.3026.0076
114/0.3 *0.62.7018.101211
1.522/0.3 *0.73.0012.101613
2.536/0.3 *0.83.507.412218
456/0.3 **0.84.104.952924
684/0.3 **0.85.103.303731
HRFR FR-LSH HFFR
TEST SPECIFICATION SPECIFIED VALUE TEST SPECIFICATION SPECIFIED VALUE TEST SPECIFICATION SPECIFIED VALUE
CRITICAL OXYGEN INDEX ASTM-D 2863 29% MINIMUM CRITICAL OXYGEN INDEX ASTM-D2863 29% MIN CRITICAL OXYGEN INDEX ASTM-D2863 29% MIN
TEMPERATURE INDEX ASTM-D2863 250° C MIN TEMPERATURE INDEX ASTM-D2863 250° C MIN
TEMPERATURE INDEX ASTM-D 2863 250°C MINIMUM ACID GAS GENERATION IEC 60754-1 20% MAX ACID GAS GENERATION IEC 60754-1 <0.5%
SMOKE DENSITY RATING ASTM-D2843 60% MAX SMOKE DENSITY RATING ASTM-D2843 60% MAX
Important Technical Notes
  • * CLASS 2: Stranded Conductor  |  ** CLASS 5: Flexible Conductor
  • The number of wires and diameter mentioned in the table are approximate and nominal. However, they shall meet the requirements of conductor resistance as per standards IS 8130.
  • The above data is indicative and may be revised without prior intimation. Johnson Cables will not be liable for any damages arising out of incorrect application.