4 Core 1.1 KV Cable

HOME LT POWER CABLES 4 CORE 1.1 KV CABLE
4 Core 1.1 KV Cable
1.1 KV Grade

4 Core 1.1 KV Cable

4 Core Aluminium/Copper Conductor XLPE Insulated Armoured/Un-Armoured Cable (Ref Spec: IS 7098 Part-1)

Cable Structure
Stranded Conductor
Core
XLPE Insulation
Layer 1
PVC Inner Sheath
Layer 2
Armouring
Layer 3

Ref Specification: IS 7098 Part-1 | Cable Code: A2XY-2XY

SIZE
(mm²)
NOMINAL INSULATION THICKNESS (mm) MINIMUM INNER SHEATH THICKNESS (mm) NOMINAL OUTER SHEATH THICKNESS (mm) APPROX OVERALL DIA OF CABLE (±2mm) APPROX WEIGHT OF CABLE (kg/km) MAX CONDUCTOR DC RESISTANCE AT 20°C (Ω/km) NOMINAL CURRENT RATING (AMPS)
A2XY 2XY ALUMINIUM COPPER ALU GROUND ALU AIR COPPER GROUND COPPER AIR
4C x 4 0.70 0.30 1.80 14.00 230 350 7.410 4.610 35 32 45 41
4C x 6 0.70 0.30 1.80 15.00 290 440 4.610 3.080 46 42 56 52
4C x 10 0.70 0.30 1.80 17.00 370 640 3.080 1.830 57 54 74 70
4C x 16 0.70 0.30 1.80 19.00 460 800 1.910 1.150 74 69 95 89
4C x 25 0.90 0.30 2.00 23.00 600 1200 1.200 0.727 95 93 122 119
4C x 35 0.90 0.30 2.00 25.50 750 1600 0.868 0.524 114 114 146 147
4C x 50 1.00 0.30 2.00 29.50 980 2150 0.641 0.387 134 138 173 179
4C x 70 1.10 0.40 2.20 33.50 1300 2900 0.443 0.268 164 175 212 226
4C x 95 1.10 0.40 2.20 37.50 1700 3900 0.320 0.193 197 216 254 279
4C x 120 1.20 0.50 2.40 41.50 2150 4850 0.253 0.153 223 249 287 320
4C x 150 1.40 0.50 2.60 46.00 2600 6000 0.206 0.124 249 284 321 365
4C x 185 1.60 0.50 2.80 50.00 3200 7450 0.164 0.0991 282 329 362 422
4C x 240 1.70 0.60 3.00 56.00 4000 9650 0.125 0.0754 327 392 418 500
4C x 300 1.80 0.70 3.20 62.00 5000 12050 0.100 0.0601 369 452 469 574

Ref Specification: IS 7098 Part-1 | Cable Code: A2XFY/2XFY

SIZE
(mm²)
NOMINAL INSULATION THICKNESS (mm) MINIMUM INNER SHEATH THICKNESS (mm) NOMINAL ARMOUR STRIP (mm) MINIMUM OUTER SHEATH THICKNESS (mm) APPROX OVERALL DIA OF CABLE (±2mm) APPROX WEIGHT OF CABLE (kg/km) MAX CONDUCTOR DC RESISTANCE AT 20°C (Ω/km) NOMINAL CURRENT RATING (AMPS)
A2XFY 2XFY ALUMINIUM COPPER ALU GROUND ALU AIR COPPER GROUND COPPER AIR
4C x 10 0.70 0.30 4 x 0.80 1.40 18.50 550 780 3.080 1.830 57 54 74 70
4C x 16 0.70 0.30 4 x 0.80 1.40 20.00 720 1050 1.910 1.150 74 69 95 89
4C x 25 0.90 0.30 4 x 0.80 1.40 23.50 950 1550 1.200 0.727 95 93 122 119
4C x 35 0.90 0.30 4 x 0.80 1.40 25.50 1050 1950 0.868 0.524 114 114 146 147
4C x 50 1.00 0.30 4 x 0.80 1.56 29.50 1350 2550 0.641 0.387 134 138 173 179
4C x 70 1.10 0.40 4 x 0.80 1.56 33.50 1700 3350 0.443 0.268 164 175 212 226
4C x 95 1.10 0.40 4 x 0.80 1.56 37.50 2100 4450 0.320 0.193 197 216 254 279
4C x 120 1.20 0.50 4 x 0.80 1.72 41.50 2600 5500 0.253 0.153 223 249 287 320
4C x 150 1.40 0.50 4 x 0.80 1.88 46.00 3000 6700 0.206 0.124 249 284 321 365
4C x 185 1.60 0.50 4 x 0.80 2.04 51.00 3700 8200 0.164 0.0991 282 329 362 422
4C x 240 1.70 0.60 4 x 0.80 2.20 57.00 4700 10300 0.125 0.0754 327 392 418 500
4C x 300 1.80 0.70 4 x 0.80 2.36 63.00 5660 12800 0.100 0.0601 369 452 469 574

Ref Specification: IS 7098 Part-1 | Cable Code: A2XWY/2XWY

SIZE
(mm²)
NOMINAL INSULATION THICKNESS (mm) MINIMUM INNER SHEATH THICKNESS (mm) NOMINAL ARMOUR WIRE (mm) MINIMUM OUTER SHEATH THICKNESS (mm) APPROX OVERALL DIA OF CABLE (±2mm) APPROX WEIGHT OF CABLE (kg/km) MAX CONDUCTOR DC RESISTANCE AT 20°C (Ω/km) NOMINAL CURRENT RATING (AMPS)
A2XWY 2XWY ALUMINIUM COPPER ALU GROUND ALU AIR COPPER GROUND COPPER AIR
4C x 4 0.70 0.30 1.40 1.24 15.50 510 590 7.410 4.610 35 32 45 41
4C x 6 0.70 0.30 1.40 1.24 16.50 590 730 4.610 3.080 46 42 56 52
Important Technical Notes
  • Note: 1. The above data is approximate & subject to manufacturing tolerance, 2. Delivery length tolerance +/- 5%.